Xylem P81630E Series VSC and VSCS Base Mounted Centrifug Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pompy Xylem P81630E Series VSC and VSCS Base Mounted Centrifug. Xylem P81630E Series VSC and VSCS Base Mounted Centrifugal Pumps User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 14
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Series VSC
®
and VSCS
®
Base Mounted
Centrifugal Pumps
INSTRUCTION MANUAL
P81630
REVISION E
INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.
(TO BE USED IN CONJUNCTION WITH VSC PARTS LIST CONTAINING LINE DRAWINGS)
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - Centrifugal Pumps

Series VSC® and VSCS® Base MountedCentrifugal PumpsINSTRUCTION MANUALP81630REVISION EINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.(TO BE US

Strona 2 - INSTRUCTION

SERVICE INSTRUCTIONS FOR PUMPS WITH FLUSH PACKING (VSC-PF, VSCS-PF)(See special instructions for pumps 10 x 12 x 17, 12 x 14 x 121/2 and 8 x 10 x 17)T

Strona 3 - IMPORTANT

11SPECIAL INSTRUCTIONS FOR PUMPS (VSCS-PF) 10 x 12 x 17 and 12 x 14 x 121/2TO REPLACE THE PACKING:4. Remove flush tube and tube fitting from inside

Strona 4 - COUPLER ALIGNMENT

12-PF START-UP INSTRUCTIONSPrior to start-up, back off packing glands or screws until glandsare loose. Re-tighten with fingers until glands are just s

Strona 5 - GENERAL INSTRUCTIONS

CAPSCREW TORQUE (FOOT-POUND)CAPSCREW HEADCAPSCREW DIAMETERTYPE MARKING1/45/163/87/161/25/83/47/8 1SAE Grade 2 6 13 25 38 60 120 190 210 300BrassStainl

Strona 6 - SERVICE INSTRUCTIONS

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.xyleminc.com/brands/bellgossettBell & G

Strona 7

DESCRIPTIONThe VSC and VSCS Series centrifugal pumps are frame mountedpumps which feature – high efficiency, rugged construction,compact design, foot

Strona 8 - 16"

ADDITIONAL SAFETY REQUIREMENTS:ELECTRICAL SAFETY:THERMAL SAFETY:MECHANICAL SAFETY:3WARNING: Electrical Shock HazardElectrical connections to be made b

Strona 9

4INSTALLATIONThis pump is built to provide years of service if installed properlyand attached to a suitable foundation. A base of concrete weigh-ing 2

Strona 10 - 4" space between

5VSCS-SVSCS-PFVSCS-DFOR FINE ALIGNMENT, ORANGE HYTREL INSERTS,3500 RPM OPERATION, OR ALL OTHER COUPLER TYPESUse a dial indicator when greater alignme

Strona 11

COVERPLATECAPSCREWSCOVERPLATEBEARINGHOUSINGCAPSCREWBEARINGCOVERCAPSCREWBEARINGCOVERBEARINGVOLUTEIMPELLERSEALSLINGERSHAFTSTANDARD SEAL CONFIGURATIONS

Strona 12 - -PF START-UP INSTRUCTIONS

7TO REPLACE THE SEALS:4. Remove the bearing cover capscrews. To release the bear-ing cam lock, loosen the allen set screw and tap the camlock counter-

Strona 13 - DEALER SERVICING

“O” RING*SHAFT SLEEVESEAL COLLARSET SCREWSROTATINGSEAL MEMBERSGASKETSEAL CARBONSEAL HOUSING1/16"REF.ASSEMBLY AIDDRIVE COLLARDRIVE COLLARSET SCREW

Strona 14 - Xylem Inc

9TO REPLACE THE SEAL OR SHAFT SLEEVE:4. Remove flush tube and tube fitting from seal housinginside bearing bracket.5. Remove bearing bracket capscrews