- 1 -
WL16 Data Logger
Covers WL16S and WL16U Data Loggers
Global
Water
Instrumentation, Inc.
151 Graham Road
P.O. Box 9010
College Station, TX 78742-9010
T: 800-876-1172
Int’l: (979) 690-5560, F: (979) 690-0440
globalw@globalw.com
11/30/09
01-404
Publication Number 38300112
Przeglądanie stron 0
1 2 3 4 5 6 ... 32 33

Podsumowanie treści

Strona 1 - WL16 Data Logger

Global Water 800-876-1172 • globalw.com - 1 - WL16 Data Logger Covers WL16S and WL16U Data Loggers Global Water Instrumentation, Inc. 151 Grah

Strona 2

Global Water 800-876-1172 • globalw.com - 10 - To make a direct connection to the logger, click the “Direct” option and from the “Port” menu, s

Strona 3

Global Water 800-876-1172 • globalw.com - 11 - Select the baud rate WL16S Only Two baud rates are supported 9600 and 19200. Should you expe

Strona 4

Global Water 800-876-1172 • globalw.com - 12 - WL16S Only Sample initialization text file: This is for reference and applies to an external US Robo

Strona 5

Global Water 800-876-1172 • globalw.com - 13 - IX. Main Screen: The main screen is where the status and option menus are accessed. The WL16 da

Strona 6

Global Water 800-876-1172 • globalw.com - 14 - Tool Bar: The tool bar at the top of the screen has 3 options; File, Action and Help. In this scree

Strona 7

Global Water 800-876-1172 • globalw.com - 15 - Records: This field indicates the number of data recordings in memory. Logging State: This shows

Strona 8

Global Water 800-876-1172 • globalw.com - 16 - Bar Graphs: The bar graphs show a visual representation of the most recent data reading taken by

Strona 9

Global Water 800-876-1172 • globalw.com - 17 - X. On-Line Help Files: Clicking on Help displays the on-line help files which contain all of the i

Strona 10

Global Water 800-876-1172 • globalw.com - 18 - XI. Get History: Clicking the Get History button begins the downloading of the historical data in

Strona 11

Global Water 800-876-1172 • globalw.com - 19 - Save to File: Clicking this button allows the data to be exported to an Excel compatible .CSV fil

Strona 12 - Connect 19200

Global Water 800-876-1172 • globalw.com - 2 - Congratulations on your purchase of a Global Water WL16 Data Logger. This instrument has been quali

Strona 13

Global Water 800-876-1172 • globalw.com - 20 - Action: The Action menu has two options, “Program Settings” and “Initialize to Default Values”. Pro

Strona 14

Global Water 800-876-1172 • globalw.com - 21 - Name: The logger is a user definable name to identify the logger. Up to 32 characters are allowed h

Strona 15

Global Water 800-876-1172 • globalw.com - 22 - Logarithmic Timing: Typically used in groundwater pump studies, this mode speeds up the sample rate

Strona 16

Global Water 800-876-1172 • globalw.com - 23 - Alarm Times: Check the box associated with each alarm to enable that feature and enter the desired

Strona 17

Global Water 800-876-1172 • globalw.com - 24 - The calibration of channel one to a water level sensor is discussed in the following example where i

Strona 18

Global Water 800-876-1172 • globalw.com - 25 - Disp High: This field sets the upper limit of the bar graph displayed in the main screen and provid

Strona 19

Global Water 800-876-1172 • globalw.com - 26 - Click on the Low EU field and enter the low engineering unit that will be used to calibrate the l

Strona 20

Global Water 800-876-1172 • globalw.com - 27 - XV. Programming Program Settings: The Program Settings button at the bottom of the setup menus wi

Strona 21

Global Water 800-876-1172 • globalw.com - 28 - XVI. Modem Cable Diagram (WL16S Only): The following wiring diagram is used to make a cable to co

Strona 22

Global Water 800-876-1172 • globalw.com - 29 - XVII. Adjusting the Zero Reference Level: The sensor on the WL16 level logger measures the depth

Strona 23

Global Water 800-876-1172 • globalw.com - 3 - I. Checklist: a. WL16S (Serial) or WL16U (USB) Data Logger b. WL16 Data Logger Manual c. WL16S c

Strona 24

Global Water 800-876-1172 • globalw.com - 30 - • Install the WL16 as it will be in the final installation. • Place a mark on the cable or logger

Strona 25

Global Water 800-876-1172 • globalw.com - 31 - Assume that you wish to set the zero reference point to the lowest water level in the data record. T

Strona 26

Global Water 800-876-1172 • globalw.com - 32 - XVIII. Maintenance: a. Except for battery and desiccant, there are no user-serviceable part

Strona 27

Global Water 800-876-1172 • globalw.com - 33 - XX. Customer Support: Call Global Water for tech support: 800-876-1172 or 979-690-5560 (many prob

Strona 28

Global Water 800-876-1172 • globalw.com - 4 - IV. WL16 Specifications: Logger: Power Supply: Two 9VDC Alkaline batteries standard 8 VDC Min. to 2

Strona 29

Global Water 800-876-1172 • globalw.com - 5 - Sensor: Sensor Element: Silicone Diaphragm, Wet/Wet Transducer Range: Level: 0-3', 0-15&apos

Strona 30

Global Water 800-876-1172 • globalw.com - 6 - V. System Requirements: Desktop or Laptop computer with: 1) Windows 98, ME, 2000, XP Vista or W

Strona 31

Global Water 800-876-1172 • globalw.com - 7 - WL16U Only The following menus apply to the Windows XP operating system. 1) Do not let Windows s

Strona 32

Global Water 800-876-1172 • globalw.com - 8 - WL16U Only 4) The Hardware Wizard searches for the driver. If Windows advises that the software

Strona 33

Global Water 800-876-1172 • globalw.com - 9 - VII. Direct Connection: 8) To confirm the installation, look in the Device Manager and find the